Sign In | Join Free | My himfr.com
Home > Environmental Test Chamber >

ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L from wholesalers
     
    Buy cheap ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L from wholesalers
    • Buy cheap ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L from wholesalers
    • Buy cheap ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L from wholesalers
    • Buy cheap ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L from wholesalers
    • Buy cheap ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L from wholesalers

    ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN8810-600L
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T
    Supply Ability : 10 sets/month
    Delivery Time : 45 days
    • Product Details
    • Company Profile

    ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L


    ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L


    Complied Standards & Clauses



    ASTM. B117-2009 Salt Spray Test

    JIS H8502 Salt Water Spray Test Method

    ISO9227 Salt Spray Test


    Product information:



    Use environment conditions:

    1. The environment temperature is 5~30 ℃, and the relative humidity is ≤ 85% R.H;

    2. The installation site must be flat and vibration free;

    3. The equipment shall be kept away from heat sources and flammable and explosive substances;

    4. The installation position shall not be directly exposed to sunlight, and the indoor air circulation shall be maintained;

    5. The equipment installation site shall be clean, and shall not be installed in the place with more dust or at the dust outlet.


    Technical Parameters



    Nominal internal volume600L
    Effective size of inner box (cm)120×100×50(L×W×H) cm
    Outline space (cm)210×125×140(L×W×H) cm
    WeightAbout 150kg
    Maximum power3KW
    Maximum current14A
    Power supply
    Power supply conditions and power supply

    1. AC 220V single-phase two-wire + protective grounding; allowable voltage fluctuation range ±10%V;

    2. The allowable frequency fluctuation range is 50±0.5HZ; TN-S mode power supply or TT mode power supply.

    3. The grounding resistance of the protective ground wire is less than 4Ω

    4. The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and this switch must independently control the use of the equipment. at the installation site, and this switch must independently control the use of the equipment.

    Performance index
    Use environmental conditions

    1. The ambient temperature is 5~30℃ and the relative humidity is ≤85%R.H;

    2. The installation site must be a flat, vibration-free ground;

    3. The equipment needs to be kept away from heat sources and flammable and explosive substances;

    4. The installation location must not be exposed to direct sunlight and maintain indoor air circulation;

    5. The equipment installation site needs to be clean and cannot be installed in dusty places or dust exhaust outlets.

    Temperature and humidity range

    Test room temperature: RT~50℃

    Pressure barrel temperature: RT~ 63℃

    Relative humidity ≥85%R.H

    Heating rate

    Test room temperature RT→+50℃≤60 min

    Pressure barrel temperature RT→+63℃≤60 min

    Main technical parameters

    Temperature resolution: 0.1℃

    Temperature deviation: ±1℃

    Temperature uniformity: 2℃

    Temperature fluctuation: ±1℃

    Spray volume (m1/80cm2/h) 1.0~2.0 (collect at least 16 hours, take the average value)

    Spray pressure: 1.00±0.01kgf/cm2

    Potion PH value: Neutral 6.0~7.0 Acidic 3.0~3.1

    Spray solution pH value: Neutral 6.5~7.2 Acidic 3.1~3.3

    Control time: 1S ~ 9999H can be set arbitrarily

    Note: The loss of carbon dioxide in the solution during spraying may cause changes in pH value. You can use the following methods, such as heating the solution to above 35°C before placing it in the test equipment, or using fresh boiling water to prepare the solution to reduce the carbon dioxide content in the solution. , can avoid changes in pH value. In order to ensure the pH value of the spray solution in the acid test or copper accelerated salt spray test, the pH value of the configured potion can be adjusted to 2.8~3.0 and check whether the solution and/or solute meets the requirements. it into the test equipment, or using fresh boiling water to prepare the solution to reduce the carbon dioxide content in the solution, which can avoid the change of pH value. The acid test or copper accelerated salt spray test is to ensure the pH value of the spray solution, Adjust the PH value of the solution to 2.8~3.0 and check whether the solution and/or solute meet the requirements.

    Structure characteristics
    Box structure

    1. The laboratory uses imported PVC boards (Korea's Xinmeile) with a thickness of 8mm and a durable temperature of 85°C.

    2. The sealing cover of the laboratory is made of imported PVC and acrylic window, with a thickness of 8mm.

    3. The reagent refill bottle adopts a hidden water level detection system, which is easy to clean and not easy to break.

    4. The saturated air bucket is made of SUS304# stainless steel high-pressure resistant bucket with the best insulation effect. An external water level bar can be used to check the water level in the saturated bucket.

    5. The test material rack adopts a flat indexing rack, and the angle can be adjusted arbitrarily to allow fogging and fogging from all sides, allowing more specimens to be placed.

    6. The sealing cover is opened and closed pneumatically.

    7. The test chamber is sealed by water to ensure that corrosive gases in the chamber do not leak.

    8. The control box and test box are integrated, and the left and right structures are easy to operate.

    9. The water and electricity separation structure is adopted to effectively prevent water from entering the electrical control box and damaging accessories.

    Cabinet coverThe sealing cover of the laboratory is made of imported PVC board and acrylic window, with a thickness of 8mm. The top is made into a 110° sealing cover, which effectively prevents condensation water from dripping onto the surface of the sample during the test and affecting the test results.
    Control panelYouyi 7-inch touch screen controller, pressure gauge, main power switch
    Power distribution control cabinetWater filling solenoid valve, spray solenoid valve, demisting solenoid valve, power distribution board, over temperature protector, air saturation pressure barrel, spray control valve.
    Heating systemUsing water vapor heating method, titanium alloy heating tube P.I.D controls heating to achieve temperature balance.
    Water make-up system

    1. Water replenishment in the test room and pressure barrel: two water replenishment control systems, manual and automatic, can be connected to the tap water pipe to automatically control water replenishment or manual water replenishment, dual replenishment mode, easy to use;

    Note: If the tap water has too many impurities or is acidic or alkaline, a filter must be installed at the water inlet.

    2. Liquid replenishment: using a large hidden water tank and manual replenishment.

    Drainage systemDrainage valve control device, manual drainage mode.
    Spray system

    Using the Bernoult principle to absorb salt water and then atomize it, the degree of atomization is uniform

    There is absolutely no blocking of crystallization, ensuring continuous testing standards.

    Nozzle made of corrosion-resistant Teflon.

    Spray modeContinuous/intermittent
    Flow controlThe peristaltic pump can supply liquid quantitatively, and the flow control range is: 0.1-580ML/M.
    Air supply systemThe spray pressure is adjusted to 1kg/cm² in two stages. The first time is to adjust the compressed air to 2kg/cm² and enter the saturated barrel for heating. The second time is to adjust the spray pressure to 1kg/cm².
    Mist exhaust system

    1. Fully automatic pressure balance mist exhaust device, just connect the mist exhaust pipe, and the mist will be automatically exhausted according to the pressure in the box

    2. Manual defogging button switch. Just click this button before opening the test chamber cover to quickly remove indoor fog.

    3. Note: The mist exhaust pipe of the machine needs to be extended to an open outdoor area, and it is necessary to avoid being close to corrosive items to prevent the mist discharged from the machine from corroding other items; the mist exhaust extension pipe must not have wavy and discounted places, and it must be avoided inside the mist exhaust pipe. Condensed water blocks the mist exhaust pipe and cannot effectively discharge exhaust gas.

    Electric control system
    Controller

    1. 7-inch touch screen controller can perform fixed-value (i.e. continuous, or constant temperature) experiments or programmable (intermittent, cycle tests) salt spray experiments. One unit can achieve multiple functions to meet customers' different salt spray experiment requirements. High-precision temperature Control module, PID automatic calculation to control temperature, high stability platinum temperature measurement probe.

    2. Standby can be set, that is, when the temperature is close to the set temperature, the instrument automatically sprays and times the time at the same time. Defogging will automatically start when the time is over, and the defogging time can be set. The water replenishment delay can effectively solve the high-frequency replenishment actions caused by water level fluctuations. Increase the life of the hydration system. English systems can meet the inspection requirements of foreign customers.

    Temperature input modeBy touch screen
    Total working timeOne-time cumulative timer can monitor the total working time of the machine
    Operation modeContinuous operation/intermittent operation.
    Temperature setting rangeThe upper and lower limits of the maximum temperature range are 5℃
    Panel displaySet temperature value, current temperature value, set time, current time, total machine working time, over-temperature abnormal indicator light, water shortage abnormal indicator light, operation end indicator light, spray status indicator light, defogger status indicator light
    Temperature measuring bodyPT100 platinum resistor
    Temperature control methodAnti-integral saturation PID, BTC balance temperature control method (temperature test equipment)
    Communication method

    Equipped with standard RS232 and network port communication interfaces, and standard modbus-rtu communication protocol, it can be realized

    Conduct remote communication management between central control instruments and computers; open communication protocols and provide communication protocols

    Negotiation instructions;

    Data output

    1. USB flash disk storage can be carried out through the USB interface, and it supports U disk hot-swap and direct download to U disk functions.

    function; and can copy data or directly display and print test data/curves through a PC.

    2. Data saving can be exported directly and the data will be automatically saved; the temperature data section to be exported can be selected through time;

    Curve record

    It has battery-protected RAM that can save the device’s setting values, sampling values ​​and sampling time;

    The maximum recording time is 360 days (when the sampling period is 60S)

    Safety protection device
    Test boxExtreme over temperature protection, water shortage protection.
    Saturated barrelExtreme over temperature protection, water shortage protection.
    Heating systemHeating pipe dry burning, abnormal water supply and drainage
    Power SupplyLeakage protection, overload, and short circuit protection
    Storage environment requirementsThe environment temperature of equipment shall be kept within 0 ℃~+45 ℃
    Requirements for the installation siteThe distance between the left and right side and rear side wall panels of the test box and the wall shall not be less than 600mm, and the distance between the front and the wall shall not be less than 800mm. When transporting equipment, whether it can enter the doorway, passage, elevator, etc., so as to avoid affecting your project progress.

    Details


    ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600LASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L


    Quality ASTM. B117 Salt Fog Corrosion Test Environmental Chamber 600L for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)