Sign In | Join Free | My himfr.com
Home > Temperature Humidity Test Chamber >

IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers
     
    Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers
    • Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers
    • Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers
    • Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers
    • Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers
    • Buy cheap IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L from wholesalers

    IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN881-1000L
    Certification : Calibration Certificate (Cost Additional)
    Payment Terms : T/T
    Supply Ability : 10 Sets Per Month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L


    IEC60068-2-2 Programmable Constant Temperature and Humidity Test Chamber 1000L


    Complied Standards & Clauses



    IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

    IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

    IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

    IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”


    Product Overview



    This test equipment prohibits:

    1.Testing or storage of flammable, explosive and volatile substance samples

    2.Testing or storage of corrosive substance samples

    3.Testing or storage of biological samples

    4.Testing or storage of samples from strong electromagnetic emission sources

    Test environment conditions: When the ambient temperature is +25℃, relative humidity ≤85%, and there is no sample in the test chamber


    Technical Parameters



    Product nameProgrammable constant temperature and humidity test chamber
    Product modelSN881-1000L
    Volume, dimensions and weight
    Nominal internal volume1000L
    Internal dimensionsW1000* H1000*D1000mm
    External dimensionsW1500* H2150*D1520mm
    WeightAbout 560kg
    Performance
    Temperature range-70℃→+150℃
    Humidity range

    (20~98)%RH

    (Temperature: 20℃~85℃, refer to the temperature and humidity controllable range chart, no active heat load)

    Temperature fluctuation±0.5℃
    Humidity fluctuation≤2.5%
    Temperature deviation≤±2.0℃
    Humidity deviation≤±3%
    Heating timeNo load average 2~3℃/min
    Cooling timeNo load average 0.7~1℃/min
    Load conditionsnone
    Work noise

    A sound level≤70dB(A)

    (Measured in a soundproof room with an ambient temperature of 25°C and low echo; A weighting is used to test the average of 9 points; each test point is 1 meter away from the noise source horizontally and 1 meter above the ground.)

    Structure

    Insulated building envelope


    ①Outer wall material: A3 board spraying

    ②Inner wall material: Brushed stainless steel plate SUS﹟304.

    ③Box insulation material: 100mm high temperature resistant rigid polyurethane foam.

    ④Door insulation material: 100mm high temperature resistant rigid polyurethane foam.

    Bottom structural strengthThe heavy capacity of the track at the bottom of the test chamber: ≤100Kg/m² (load)
    Air conditioning channel

    ① Stainless steel long-axis centrifugal fans: 4 units/90W.

    ②Fan, heater, evaporator (also dehumidifier), drainage device, pressure balance port, adjustable air guide plate, temperature sensor

    Standard configuration of test chamber

    ①Window 400x600x40mm 3-layer vacuum tempered glass.

    ②Flat embedded handle,

    ③Door hinge: SUS #304 imported hinge

    ④ Energy-saving lamps in the box: LED energy-saving lamps

    ⑤Lead hole: φ50mm 1 piece

    Box door

    ①The single-piece door opens outwards, with the hinge on the left and the handle on the right (when facing the front of the box).

    ② Equipped with a safety door locking mechanism (the door can be opened in the test room), the door is equipped with electric heat to prevent condensation, and the viewing range of the insulating glass observation window is approximately (W400×H600mm). Electric heating device to prevent condensation on door frame

    Control PanelThe controller is a 600 7-inch display screen, temperature (humidity) control display screen, operating indicator light, and lighting button
    Mechanical roomRefrigeration unit, compressor water tray, pressure relief device, heating device
    Distribution CabinetDistribution board, cooling fan, main power switch, transformer, intermediate relay, time relay, solid state relay, AC contactor, circuit breaker
    Heater

    ① Fin-type heat pipe-shaped stainless steel electric heater

    ②Heating control method: SSR (Solid State Relay) contactless equal period pulse width modulation

    ③Heating power: about 4KW

    Power cord holeLocated on the back of the box
    Cooling System
    Hot and cold equipment

    ① Hitachi or Emerson low-temperature and low-noise vortex ultra-low temperature refrigeration system (air-cooled heat dissipation method).

    ②Cooling method: air cooling

    Hot and cold exchange deviceTwo-stage refrigeration system Hitachi or Emerson low-noise scroll compressor. Adopting ultra-high efficiency SWEP cold coal heat and cold exchange design [made in Sweden (sus#316)], it is more efficient than the traditional internal spiral type.
    Heating load regulation

    ①Adopt automatic adjustment of cold coal flow device to effectively take away the heating load of the product to be tested and German/Japanese technology

    Technological synchronization.

    ②Compared with the traditional design, the control stability and reproducibility are higher, and it achieves super efficiency of saving power and saving more energy.

    Refrigeration CompressorsHitachi or Emerson
    High efficiency components

    ①The condenser and evaporator adopt AC&R double spoiler type aluminum fin device.

    ②The throttling devices adopt imported Chiming refrigeration accessories.

    Expansion systemCapacity controlled refrigeration system (capillary tube).
    Evaporative condenserAll copper tube heat exchanger.
    Refrigerator control method

    ①The controller of the control system automatically adjusts the operating conditions of the refrigerator according to the test conditions.

    ②Evaporation pressure regulating valve.

    ③Compressor return air cooling circuit

    ④ The refrigeration system is designed with vibration and noise reduction measures such as shock absorber tubes.

    RefrigerantHoneywell R404a (ozone depletion index is 0)
    Electrical control system
    Controller model600 Touch Intelligent Programmable Temperature Controller
    Controller specifications

    Technical indicators:

    1. 7-inch true color touch screen

    2. Two control methods: program/set value

    3. Sensor type: two PT100 inputs (electronic sensor input optional)

    4. Output mode: voltage pulse (SSR)/control output: 2 channels (temperature/humidity)/2 channels 4-20mA analog output/16 channels relay output (passive)

    5. Control signals: 8 channels IS control signals/8 channels T control signals/4 channels AL control signals

    6. Alarm signal: 16 DI external obstacle alarms

    7. Temperature measurement range: -90.00℃--200.00℃, (optional -90.00℃--300.00℃) error ±0.2℃;

    8. Humidity measurement range: 1.0%--100%RH, error ±1%RH;

    9. Communication interface: (RS232/RS485, the longest communication distance is 1.2km [optical fiber can reach 30km]);

    10. Interface language type: English

    11. Equipped with Chinese character input function;

    12. Can bring a printer (USB function optional);

    13. Multiple signal combination relay outputs, the signals can be subjected to logical operations (NOT, AND, OR, NOR, XOR),

    Referred to as PLC programming ability;

    14. Diversified relay control methods: parameter->relay mode, relay->parameter mode, logic combination

    mode, composite signal mode;

    15. Program editing: 120 groups of programs can be programmed, and each group of programs can have a maximum of 100 segments;

    Controller technical parameters

    Accuracy: temperature ±0.1℃+1digit, humidity ±1%R.H+1digit

    Resolution: temperature ±0.01℃, humidity ±0.1%R.H.

    Temperature slope: 0.1~9.9 can be set.

    It has upper and lower limit standby and alarm functions.

    Temperature and humidity input signal dry and wet bulb PT100x2.

    9 sets of P.I.D control parameter settings, P.I.D automatic calculation.

    Dry and wet bulb automatic correction screen

    Control method

    ①Anti-integral saturation PID

    ②BTC balanced temperature control method + DCC intelligent cooling capacity control + DEC intelligent electrical control (temperature test equipment)

    ③BTHC balanced temperature and humidity control method + DCC intelligent cooling capacity control + DEC intelligent electrical control (temperature and humidity test equipment)

    Screen display function

    1. It adopts screen conversation style, no key input is required, and the options can be directly touched on the screen.

    2. Temperature set (SV) and actual (PV) values ​​are directly displayed.

    3. It can display the currently executing program number, segment, remaining time and number of cycles.

    4. Operation accumulated time function.

    5. The temperature program setting value is displayed in a graphic curve, with the function of real-time display of program curve execution.

    6. It has a separate program editing screen, and at least 5 segments of temperature, humidity and time can be input on each page.

    7. Chinese and English can be switched at will.

    8. The fault prompt screen is displayed.

    9. The screen backlight can be adjusted.

    10. The screen display protection function can be set to timer, TIMER or manual shutdown.

    Program capacity and control functions

    1. Usable program groups: maximum 120 PATTEN.

    2. Usable memory capacity: 12000 SEGMENTS in total.

    3. Repeatable execution of commands: each command can be executed up to 3200 times.

    4. The program is created in a conversational style, with functions such as editing, clearing, and inserting.

    5. SEGMENTS time setting 0~99Hour59Min.

    6. Programmable timing control module device x2 set.

    7. It has a power-off program memory, and automatically starts and resumes program execution after power is restored.

    8. With RS-485 or RS-232 communication interface.

    9. Graphical curves can be displayed in real time when the program is executed.

    10. It has the function of automatically adjusting the freezing capacity.

    11. It has scheduled start-up and shutdown functions.

    12. With date and time adjustment function.

    13. Button and screen lock (LOCK) function.

    Safety protection device
    Cooling System

    Compressor overheating

    Compressor overflow

    Compressor overpressure

    Test chamber

    Adjustable over-temperature protection device

    Air conditioning channel extreme overtemperature

    Fan motor overheated

    Other

    Leakage Protection

    Heating tube no air drying protection

    Overload and short circuit protection

    Power outage protection

    low water level protection

    Other configurations
    Sample main power leakage circuit breakerAC380V, 50Hz, three-phase four-wire + protective ground wire.
    Other special instructions
    Power cable5-core (three-phase four-wire + protective ground wire) cable 4 meters, 1 piece (can be provided according to customer requirements)
    Lead hole1 lead hole with rubber plug, diameter φ50mm, its location and quantity can be customized according to user requirements as long as the box structure allows and does not affect performance.
    TransportationCar packaging and transportation
    Conditions of UseList the conditions
    Installation site

    Flat ground and good ventilation

    No strong vibration around the device

    There is no strong electromagnetic field influence around the device

    There are no flammable, explosive, corrosive substances and dust around the equipment

    Leave appropriate space for use and maintenance around the equipment, as shown in the figure below:

    AB distance is about 1 meter


    Environmental conditions① Temperature: 5℃~35℃ ②Relative humidity: ≤85% ③Air pressure: 86kPa~106kPa
    Power supply conditionsAC380V three-phase four-wire + protective ground wire
    Power supply

    Allowable voltage fluctuation range: AC (380±10) V

    Allowable frequency fluctuation range: (50±0.5) Hz

    The grounding resistance of the protective ground wire is less than 4Ω

    The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and this switch must be independent for use by the equipment.

    Battery capacityAbout 11kW
    Maximum current30A
    Switch63A (molded case leakage protector)
    Requirements for storage environmentWhen the equipment is not working, the ambient temperature should be kept within 0℃~+45℃

    Details



    IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000LIEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L


    Quality IEC60068-2-2 Programmable Constant Temperature And Humidity Test Chamber 1000L for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)