Sign In | Join Free | My himfr.com
Home > Electrical Safety Testing Equipment >

New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles from wholesalers
     
    Buy cheap New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles from wholesalers
    • Buy cheap New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles from wholesalers
    • Buy cheap New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles from wholesalers

    New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SNE6804A
    Certification : Calibration Certificate (Cost Additional)
    Payment Terms : T/T
    Delivery Time : 30 days
    Supply Ability : 30 sets/month
    Price : Customized
    • Product Details
    • Company Profile

    New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles


    ISO 6469 Electrical Safety Analyzer for Electrical and Hybrid Vehicles


    Complied Standards & Clauses



    ISO 6469-1:2019 Electrically propelled road vehicles — Safety specifications — Part 1: Rechargeable energy storage system (RESS)


    IEC 62196:2020 Plugs, socket-outlets, vehicle connectors and vehicle inlets-Conductive charging of electric vehicles

    ...


    Equipment Overview



    With the rapid development of new energy vehicles, the automotive aftermarket that stands behind the car companies has also attracted much attention. Car-related services that occur in the process of using new energy vehicles, such as repairs and maintenance, vehicle modification, and vehicle inspections, need to be tested for the safety of the vehicle again. For 4S shops, vehicle management offices and other places of use, we have specially developed the SNE 68 series of special safety analyzers for new energy vehicles.


    Test Project

    1. Potential equalization test:

    The resistance value of the connection between all exposed conductive shells and the electric platform; the resistance between any two exposed conductive shells that can be touched at the same time.


    2. Insulation resistance of the charging socket:

    Whether the insulation resistance between the phase line terminals of the vehicle's AC charging socket or the positive and negative terminals of the DC charging socket and the electric platform can meet the requirements.


    3. Vehicle insulation resistance test:

    It is used to detect whether the vehicle-level insulation resistance can meet the requirements. It is divided into the insulation resistance of the circuit containing the B-level voltage power supply and the insulation resistance of the B-level voltage load without the power supply.


    4. Insulation detection function verification:

    The vehicle has an insulation resistance detection function. This item is used to detect whether the vehicle can normally transmit an alarm signal to the driver when the vehicle's insulation fails.


    Functions and Features

    1. Multifunctional integration: potential equalization, charging socket insulation, vehicle insulation (battery pack insulation), insulation resistance monitoring and testing;


    2. Support vehicle VIN scanning function, can automatically call corresponding test parameters and steps, and store and print test data in association: data storage, query filtering, information management;


    3. Perfect protection: The device will not start high voltage detection if the plug is not plugged in; pulling out the plug in the detection state will cut off the power supply to the socket:


    4. Scan code start, button start, remote control starts and other start methods to meet the needs of different customers.


    5. Using 4U standard size, 10.1-inch touch screen, the operation is more concise;


    6. More channel tests can be customized as needed.


    Main Configuration

    Standards appliedISO 6469, IEC 62196, etc
    ModelSNE6804A
    Display method10.2-inch LCD
    Testing objectsElectric/hybrid vehicles
    Storage methodUSB
    Alarm methodSound and light alarm: buzzer, indicator light, three-color warning light
    Standard configuration functionExternal warning lightStandard three-color warning light
    Remote switch functionStandard remote control foot switch, external start signal can be connected
    Switch output interfaceQualified, unqualified, testing
    Dedicated detection softwareNew energy vehicle special detection software
    Printer interfaceCan be equipped with label printer or sticker printer as standard
    Barcode gun interfaceVIN and main part number identification, bar code, two-dimensional code
    Other interfacesUSB port, network port, etc.
    OtherCustomizable

    Technical Parameters



    Potential equalizationRated output32A/600mΩ/8VDC max.
    Dc current output

    Range: 3.00~32.00a

    Resolution: 0.01a

    Accuracy: ± (1%×reading value+0.2a)
    Resistance measurement range0.0-600.0mΩ
    Resistance measurement accuracy± (1%×reading value+3mΩ)
    Testing time

    Range: (0.0,0.1~999.9) s

    Resolution: 0.01s

    Accuracy: ± (0.1%×setting value+0.05s)
    Charging socket insulationRated output1kvdc/10gΩ
    Dc voltage outputRange: (100~1000) vdc
    Resolution: 1v
    Accuracy: ± (1%×setting value+2v)
    Insulation resistance measurementRange: 0.050mΩ~10gΩ
    Resolution: 0.001mΩ/0.01mΩ/0.1mΩ/1mΩ
    Resistance judgment error(100-499) v, 0.050mΩ~2.000gΩ, ± (5% reading value + 2 words)
    (500-1000) v, 0.050~999.9mΩ, ± (2%×reading value+2 words)
    1.000g~10.00gΩ, government (5%×setting value+2 words)
    Ramp up timeRange: (0.1~999.9) s
    Delay judgment timeRange: (0.3~999.9) s
    Slow down timeRange: (0.0~999.9) s
    Testing timeRange: (0.0~999.9) s
    Discharge timeNo load ≤50ms, capacitive ≤200ms
    Charging lower limit current(0.0~3.5)ua
    Entire vehicle insulation resistanceInsulation resistance setting range

    Upper limit: 0 (closed)

    0.00-100.00mΩ

    Lower limit: 0.00-100.00mΩ
    Insulation resistance measurement range0.20-100.00mΩ
    Insulation resistance measurement accuracy± (2% of reading value + 2 words)
    Test time setting range0.0-999.9s 0.0=continuous output
    Insulation detectionTest time setting range0.0-999.9s 0.0=continuous output
    Test time accuracy± (0.1% setting value+0.05s)
    Judgment typeWhether the car insulation detection is normal and alarms

    Quality New Energy Car Electrical Safety Analyzer ISO 6469 For Hybrid Vehicles for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)