    Brand Name : Sinuo
    Model Number : SNDCI96
    Certification : Calibration Certificate (Cost Additional)
    Payment Terms : T/T
    Delivery Time : 30 days
    Supply Ability : 20 sets/month
    Price : Customized
    • Product Details
    • Company Profile

    Programmable DC Power Supply For Electric Vehicle Electrical Components

    Programmable DC Power Supply for Electric Vehicle Electrical Components
    Equipment Overview


    SNDCI96 series programmable DC power supplies have significant advantages such as high power, high current, fast response, fast load transient response, low noise, and convenient use! This series of power supplies has ultra-high-power density and is a DC programmable power supply with exquisite appearance, small size, high performance, powerful functions and simple operation. It is widely used in industries such as DC motor testing, aerospace and defense, consumer electronics, computers and peripherals, communications, medical equipment, solar energy and automotive electronics.


    The SNDCI96 series requires a 5kW power module at the core of the power supply. According to the output voltage requirements, 1 to 3 modules can be configured into a chassis, which can deliver 5kW to 15kW of power. The combination of these enclosures can then be easily connected in parallel to provide up to 150 kW of power. Parallel power supplies operate like a single power supply, providing a total system current. Advanced can only be controlled. The power supply can enable complex sequence output and constant power mode through the control device, and can store/recall the settings of the instrument. The serial cycle use of this series of power supplies becomes an ideal choice for repeated testing.


    Main Features

    1. High power density, 3U standard chassis, power up to 15kW.


    2. Wide voltage range, from 0~40 to 0~1000V, single machine power 5~15kW.


    3. Fast load transient response to prevent unwanted voltage excursions.


    4. High precision, 16-bit AD internally, low ripple


    5. Flexible operation interface, convenient for users to operate


    6. It can realize output parallel connection and modular design, which is convenient for users to expand capacity.


    7. Sequence function, flexible and diverse system control, to meet customer testing needs.


    8. Variable speed fan with low noise and low temperature change control.


    9. With constant voltage and constant current output modes.


    10. Complete input over-under-voltage, lack of phase, internal over-heating, output over-voltage and other protections, and safety performance is guaranteed.


    11. With analog control interface, power output can be controlled separately through external analog interface.


    Technical Parameters


    Model

    SNDCI96

    150-33

    SNDCI96

    150-66

    SNDCI96

    150-100

    SNDCI96

    200-25

    SNDCI96

    200-50

    SNDCI96

    200-75

    AC inputPhases: 3 phases 3 wires + grounding; Voltage: 380VAC±10%; Frequency: 47~63Hz; Power factor: ≥0.78
    DC outputVoltage0~40V0~60V
    Current0~125A0~250A0~375A0~83A0~167A0~250A
    Power0~5kW0~10kW0~15kW0~5kW0~10kW0~15kW
    Efficiency87%, typical value under nominal line and maximum load

    Program

    Accuracy

    Voltage≤± (0.05% +0.05% FS)
    Current≤± (0.2% +0.2% FS)
    OVP≤±1%FS (Programming range: 5-110% from the front panel, remote analog input terminal or optional digital input configuration)
    Readback accuracyVoltage≤± (0.05% +0.05% FS)
    Current≤± (0.2% +0.2% FS)
    Ripple and noise

    RMS

    (20Hz-300KHz)

    20mVrms20mVrms20mVrms20mVrms20mVrms20mVrms

    P-P

    (20Hz-20MHz)

    75mVpp75mVpp75mVpp75mVpp75mVpp75mVpp
    Current mode<±0.04% of full scale RMS current
    Source effectVoltage≤0.01% FS (±10% UAC input)
    Current≤0.05% FS (±10% UAC input)
    Load effectVoltage≤0.02% FS (0-100% of load regulation range)
    Current≤0.1% FS (0-100% UAC of load regulation range)
    Stimulate interfaceSpecificationBuilt-in 25 one-pin D-Sub female plug
    Signal range0~5V or 0~10V
    U/I accuracyU programming: ≤0.25%FS; U read back: ≤ ± 1.0% FS; I programming: ≤0.8%FS; I read back: ≤ ± 1.0% FS
    Dynamic response timeThe taking time of load regulationUnder 50% to 100% or 100% to 50% load change, return to ±0.75% full-scale steady-state output within 1ms
    Output voltage rise timeMaximum 100ms (10~90% full scale)
    Current slew rate45A/MS (typical value)
    StabilityUnder the condition of the same operating environment, after 30 minutes of warm-up, it usually stays within ±0.05% of the set value within 8 hours
    Communication interfaceRS232/RS485/CAN/LAN/UBS and etc. interfaces
    Parallel operationUp to 5 products can be connected, and 61 power supplies in parallel will reduce the accuracy of each power supply by 0.3%
    Tandem operationUp to 2 units in series
    Working environmentIndoor type; working temperature: 0~50℃, humidity: <80%, no condensation, storage temperature: -20~70℃, altitude <2000m

    Temperature coefficient


    0.02%/℃ maximum rated output voltage, under voltage set point, typical value
    0.03%/℃ maximum rated output current, under current set point, typical value
    Output floating voltageThe negative terminal is within ±300V of the chassis potential
    Volume: W*H*D (mm)482mm*609mm*132mm (W*H*D) standard cabinet, height 3U
    Weight22Kg28Kg34Kg22Kg28Kg34Kg
    Model

    SNDCI96

    80-63

    SNDCI96

    80-125

    SNDCI96

    80-188

    SNDCI96

    100-50

    SNDCI96

    100-100

    SNDCI96

    100-150

    AC inputPhases: 3 phases 3 wires + grounding; Voltage: 380VAC±10%; Frequency: 47~63Hz; Power factor: ≥0.78
    DC outputVoltage0~80V0~100V
    Current0~63A0~125A0~188A0~50A0~100A0~150A
    Power0~5kW0~10kW0~15kW0~5kW0~10kW0~15kW
    Efficiency87%, typical value under nominal line and maximum load

    Program

    Accuracy

    Voltage≤± (0.05% +0.05% FS)
    Current≤± (0.2% +0.2% FS)
    OVP≤±1%FS (Programming range: 5-110% from the front panel, remote analog input terminal or optional digital input configuration)
    Readback accuracyVoltage≤± (0.05% +0.05% FS)
    Current≤± (0.2% +0.2% FS)
    Ripple and noise

    RMS

    (20Hz-300KHz)

    20mVrms20mVrms20mVrms20mVrms20mVrms20mVrms

    P-P

    (20Hz-20MHz)

    100mVpp100mVpp100mVpp100mVpp100mVpp100mVpp
    Current mode<±0.04% of full scale RMS current
    Source effectVoltage≤0.01% FS (±10% UAC input)
    Current≤0.05% FS (±10% UAC input)
    Load effectVoltage≤0.02% FS (0-100% of load regulation range)
    Current≤0.1% FS (0-100% UAC of load regulation range)
    Stimulate interfaceSpecificationBuilt-in 25 one-pin D-Sub female plug
    Signal range0~5V or 0~10V
    U/I accuracy

    U programming: ≤0.25%FS; U read back: ≤ ± 1.0% FS; I programming: ≤0.8%FS;

    I read back: ≤ ± 1.0% FS

    Dynamic response timeThe taking time of load regulationUnder 50% to 100% or 100% to 50% load change, return to ±0.75% full-scale steady-state output within 1ms
    Output voltage rise timeMaximum 100ms (10~90% full scale)
    Current slew rate45A/MS (typical value)
    StabilityUnder the condition of the same operating environment, after 30 minutes of warm-up, it usually stays within ±0.05% of the set value within 8 hours
    Communication InterfaceRS232/RS485/CAN/LAN/UBS and etc. interfaces
    Parallel operationUp to 5 products can be connected, and 61 power supplies in parallel will reduce the accuracy of each power supply by 0.3%
    Tandem operationUp to 2 units in series
    Working environmentIndoor type; working temperature: 0~50℃, humidity: <80%, no condensation, storage temperature: -20~70℃, altitude <2000m

    Temperature coefficient


    0.02%/℃ maximum rated output voltage, under voltage set point, typical value
    0.03%/℃ maximum rated output current, under current set point, typical value
    Output floating voltageThe negative terminal is within ±300V of the chassis potential
    Volume: W*H*D (mm)482mm*609mm*132mm (W*H*D) standard cabinet, height 3U
    Weight22Kg28Kg34Kg22Kg28Kg34Kg
    Model

    SNDCI96

    600-8

    SNDCI96

    600-17

    SNDCI96

    1000-25

    SNDCI96

    1000-5

    SNDCI96

    1000-10

    SNDCI96

    1000-15

    AC inputPhases: 3 phases 3 wires + grounding; Voltage: 380VAC±10%; Frequency: 47~63Hz; Power factor: ≥0.78
    DC outputVoltage0~600V0~1000V
    Current0~8A0~17A0~25A0~5A0~10A0~15A
    Power0~5kW0~10kW0~15kW0~5kW0~10kW0~15kW
    Efficiency87%, typical value under nominal line and maximum load

    Program

    Accuracy

    Voltage≤± (0.05% +0.05% FS)
    Current≤± (0.2% +0.2% FS)
    OVP≤±1%FS (Programming range: 5-110% from the front panel, remote analog input terminal or optional digital input configuration)
    Readback accuracyVoltage≤± (0.05% +0.05% FS)
    Current≤± (0.2% +0.2% FS)
    Ripple and noise

    RMS

    (20Hz-300KHz)

    60mVrms60mVrms60mVrms60mVrms60mVrms60mVrms

    P-P

    (20Hz-20MHz)

    350mVpp350mVpp350mVpp350mVpp350mVpp350mVpp
    Current mode<±0.04% of full scale RMS current
    Source effectVoltage≤0.01% FS (±10% UAC input)
    Current≤0.05% FS (±10% UAC input)
    Load effectVoltage≤0.02% FS (0-100% of load regulation range)
    Current≤0.1% FS (0-100% UAC of load regulation range)
    Stimulate interfaceSpecificationBuilt-in 25 one-pin D-Sub female plug
    Signal range0~5V or 0~10V
    U/I accuracy

    U programming: ≤0.25%FS; U read back: ≤ ± 1.0% FS; I programming: ≤0.8%FS;

    I read back: ≤ ± 1.0% FS

    Dynamic response timeThe taking time of load regulationUnder 50% to 100% or 100% to 50% load change, return to ±0.75% full-scale steady-state output within 1ms
    Output voltage rise timeMaximum 100ms (10~90% full scale)
    Current slew rate45A/MS (typical value)
    StabilityUnder the condition of the same operating environment, after 30 minutes of warm-up, it usually stays within ±0.05% of the set value within 8 hours
    Communication InterfaceRS232/RS485/CAN/LAN/UBS and etc. interfaces
    Parallel operationUp to 5 products can be connected, and 61 power supplies in parallel will reduce the accuracy of each power supply by 0.3%
    Tandem operationUp to 2 units in series
    Working environmentIndoor type; working temperature: 0~50℃, humidity: <80%, no condensation, storage temperature: -20~70℃, altitude <2000m

    Temperature coefficient


    0.02%/℃ maximum rated output voltage, under voltage set point, typical value
    0.03%/℃ maximum rated output current, under current set point, typical value
    Output floating voltageThe negative terminal is within ±300V of the chassis potential
    Volume: W*H*D (mm)482mm*609mm*132mm (W*H*D) standard cabinet, height 3U
    Weight22Kg28Kg34Kg22Kg28Kg34Kg